Goyen Diaphragm Repair Kit K2546
Goyen CAC25T4 RCAC25FS4 CAC25DD4 Diaphragm repair kit K2546 AG8113901 Shockwave membrane.
- Description
- Size Guide
- Additional information
- Store Policies
- Inquiries
Description
Description
Model:: | K2546 | Body Material: | Aluminium Alloy |
---|---|---|---|
Seal Material: | Shockwave | Protection Class: | IP65 With Cable Plug |
High Light: | aro diaphragm pump repair kit, diaphragm pump repair kit, K2546 Diaphragm Repair Kit |
Goyen CAC25T4 RCAC25FS4 CAC25DD4 Diaphragm repair kit K2546 AG8113901 Shockwave membrane
DESCRIPTION
High-performance diaphragm valve with threaded ports. Equipped with ‘Shockwave’ springless diaphragm. The 4 series valves are available as remote pilot valves and may be converted to an integral pilot using either the RCA3DM or RCA3PV screw-in pilots. Outlet is at 90° to inlet.
SUITABLE FOR
Dust collector applications, in particular for reverse pulse jet filter cleaning and its variations, including bag filters, cartridge filters and envelope filters, ceramic filters and sintered metal fibre filters.
CONSTRUCTION
Body: Aluminium (diecast)
Screws: 304 Stainless steel
Diaphragm: Proprietary highperformance engineering thermoplastic Elastomer or fluororubber
The installment introduction:
1. First, Confirm the pulse valve in good condition and then installed
2. Pulse valve will be installed directly the outer wall of flange of gas manifold. The spray pipe across the gas manifold. According to the drawing and manual, the pulse valve matching appropriate spray pipe and installation. To avoid the valve install in the air manifold bottom. If the pulse valve matched trachea and connector, the connector will be used for sealing purpose only. It can not as structural support components. It can not rely on the straight connector fixed spray torch and package. The spray pipe and air manifold must be fixed independent.
3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten the trachea, torsion of 20 N*m.
4. The connection control wire needs connect of every electric control valve seat. Pay attention to the line adown to prevent rain waterproof. Or through the joint and nylon pipe, it will connect the pulse valve and electromagnetic assembly boxes of nylon pipe connection.
5. To ensure that provide compressed air clean and dry. The air manifold system provides moderate pressure and check for leaks installation. ( it can brush on soap and water, check whether the interface is bubble). Pressure was carried out on the air bag inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa), recommend for air pressure 0.8 mpa maximum
6. Testing the pulse valve blowing, listening all the pilot valve whether it is normal operation and whether the pulse blowing sound is clear.
OPERATION
Recommended on-time range: 50 to 500 ms
Recommended time between
pulses: 1 minute or greater
APPROVALS
The RCAC25T4 meets the requirements of the European Low Voltage Directive 2006/95/EC, when fitted with the RCA3PV pilot.
Please Note: We recommend using Schedule 40 pipe. Thickness OD is as shown below.
Size Guide
Additional information
Additional information
Weight | 15.2 kg |
---|---|
Dimensions | 335 × 285 × 540 cm |
Store Policies
Inquiries
General Inquiries